Motorola Lightning Board Specs The MLB series boards are designed to protect 24vac and 24vdc Motorola Irrigation Control systems from the harmful effects of lightning strikes. It has 8, 12, or 14 protected outputs with Manual, Automatic, and Off modes with 2 protected data input lines. Valve Output SpecsNormal output operating voltage: 24 Volts AC, 24 Volts DC Stage one:clamping response time: 1 ns max discharge current: 20 kA clamping voltage: 75 Volts DC +/- 20% Stage two:Normal operating current: .750 amps saturation current: 1 amp Stage three:joules: 23.0 max discharge current: 2k clamping voltage: 47 Volts DC Stage four:hold current: 1.1 amps trip current: 2.2 amps voltage level: 60 volts Data Input SpecsNormal input operation voltage: 30-35 Volts DC Stage one:clamping responce time: 1 ns max discharge current: 20 kA clamping voltage: 75 Volts DC +/- 20% Stage two:Normal operating current: .750 amps saturation current: 1 amp Stage three:joules: 8.8 clamping voltage: 38 Volts DC max discharge current: 1kA Stage Four:power rating: 1500 watts clamping voltage: 39 Volts DC Physical dimensions5.000 inches x 6.500 inches
© Control Tech USA, Inc 2005 |